EroelectronicEroelectronic

FKS
Controller 1/32 DIN

SMART function for the self-tuning of control parameters. TC, RTD or linear input programmable. Output power OFF function. Soft start function (timed output power limiting). Loop break alarm function (Alarm of anomalous condition in the control loop). Switching power supply (from 100 to 240 V AC or 24 V AC/DC). CE approved for residential and industrial environment. IP 65 and NEMA 4X front protection. FKS

LDS
LMS
LHS

1/16 DIN 3 digits temperature controllers

Dual 3 digits display or single display plus deviation barograph. Process, band, deviation or instrument malfunction alarm. Soft start function (timed output power limiting). Output power OFF function. Programmable offset on the measured value. IP 65 and NEMA 4X front protection. LDS LMS LHS

LFS - LFS mA

1/16 DIN 4 digits controller

Load current measurement (in Amps) with output failure alarm. Soft start function (timed output power limiting). Output power OFF function. RS-485 serial communication interface. Rear-of-board version. IP 65 and NEMA 4X front protection. LFS-mA Isolated 20 mA linear output programmable as: - control output - analog retransmission of the measured value. - analog retransmission of the operative set point. RS-485 serial communication interface. Rear-of-board version. IP 65 and NEMA 4X front protection.

LFS LFS ma

TMS

1/8 DIN 3 digits temperature controller

Configurable outputs (relay or SSR). Load current measurement (in Amps) with output failure alarm. Process, band, deviation or instrument malfunction alarm. Soft start function (timed output power limiting). Output power OFF function. Programmable offset on the measured value. IP 65 and NEMA 4X front protection.

TMS

MKC - PKC

1/4-1/8 DIN High performance controllers

Up to 4 independent digital outputs programmable as control outputs, events or alarms. Up to 2 independent analog outputs programmable as control outputs or analog retransmission's. Preprogrammable output for the linearization of equal percentage or quick opening valves. Split range of the output function. Alarms on the control output percentage. Load current measurement (in Amps) with output failure alarm. Three programmable logic inputs. Remote set point input. 24 V DC auxiliary power supply for transmitters. RS-485 ModBus/JBus serial communication. IP 65 and NEMA 4X front protection. MKC PKC

MKP - PKP

1/4-1/8 DIN Programmers Controllers Set point generators

200 pattern steps programmable and divisible in up to 90 single programs + 9 linked programs (sequence of single programs) 5 groups of control parameters applicable to each different pattern of program. Tracking and Guaranteed soak functions to assure the exact correspondence between controlled variable and the program set. 14 digital outputs programmable as control outputs, alarms, timer events or related to the pattern, status (RUN/HOLD) or end of cycle indications. Clock calendar function for the automatic start, daily or weekly, of a selectable program. Output power OFF function. Up to 2 independent analog outputs programmable as control outputs or analog retransmission's. Logic inputs for the RUN/HOLD status selection, for the ABORT function activation and for the program selection. RS-485 ModBus/JBus serial communication. IP 65 and NEMA 4X front protection. MKP PKP

LHI - LHL - LFS mA

1/16 DIN Safety limiters, indicators and transmitters

Universal input (TC, RTD, linear) IP 65 and NEMA 4X front protection. Rear-of-board version. LHL Limitrol - Safety limiter High limit, low limit or high and low limits with specialized reset functions. LHI - Indicator Two independent alarms with either manual or automatic reset or silence function. LFS mA - Transmitter Isolated retransmission of the measured value. Universal input (TC, RTD, mV, mA, V). Two independent alarms. LHI LHL LFS ma

TIS
Digital Programmable indicator

DPS
Indicator and transmitter

DPL
Digital programmable indicator with linear input

TIS
Digital programmable indicator Programmable TC, RTD and linear input. Switching power supply from 100 to 240 V AC. Up to 3 independent alarms with auto or manual reset. Maximum and minimum data hold. Analog retransmission of the linearized measure. IP 65 and NEMA 4X front protection.

DPS
Panel indicator and transmitter Programmable TC, RTD and linear input. Programmable square root extraction. Ten-segment programmable input linearization. Maximum and minimum data hold. RS 485 serial interface. Analog retransmission of the linearized measure. Switching power supply from 100 to 240 V AC. Two independent alarms with auto or manual reset. IP 65 and NEMA 4X front protection.

DPL
Digital programmable indicator with linear input Four digits + dummy zero display. Switching power supply from 85 to 264 V AC or 24 V AC/DC. Programmable digital filter on the measured value. 24 V DC auxiliary power supply for 2 and 4 wires transmitters. Analog retransmission of the measured value. RS 485 serial interface. Two independent alarms with auto or manual reset. Maximum and minimum data hold. IP 65 and NEMA 4X front protection.

TIS DPS DPL
 